7
Magnet Installation
M
High Magnet
Position
M
Low Magnet
Position
8
Magnet Placement Guide
Using Side Reed SW
=
Alarm to N/C
Metal Surface
Timber Surface
X
15mm
22mm
M
+13mm to
+13mm to
Y
Magnet
-13mm
-15mm
In
High
Z
35mm
39mm
Position
X
7mm
20mm
M
+9mm to
+13mm to
Y
Magnet
-12mm
-17mm
In
Low
Z
42mm
48mm
Position
For best performance install the magnet as close as pos-
sible to the RF113, and align the centre of the magnet
with the alignment mark on the RF113 housing. Use the
tables in section 8 as a guide to placement performance
in your installation.
Magnet Alignment Mark
=
Y+
M
X
Magnet
In
High
Y-
Position
M
Z
Magnet
In
Low
Position
9
Using Adhesive Mounting
The RF113 is supplied with a double sided tape
mounting option. Use this mounting method to speed
installation where appropriate.
Follow the guidelines below for best results.
1) Do not use on rough or uneven surfaces.
2) Clean both surfaces using isopropyl alcohol wipes
before installing tape.
3) Test zone function to ensure correct placement before
removing backing tape.
4) Apply firm pressure to the device for 30 seconds
after placement to ensure the adhesive activates. (The
adhesive is pressure activated)
Using Side Reed SW
N/C to Alarm
Metal Surface
Timber Surface
X
16mm
23mm
+13mm,
+13mm,
X
Y
-13mm
-15mm
Z
37mm
41mm
X
8mm
22mm
+10mm,
+13.5mm,
Y
-13mm
-17mm
Z
43mm
50mm
10
LED Indicator
6 Slow Flashes
4 Fast Flashes
Continuous Flash
Single Pulse
When panel is in service mode and device Tamper is
triggered, the LED will activate for up to 15 minutes to
assist with device placement and configuration. During
normal operation, the LED is off to extend battery life.
RF113 Device Specifications
Parameter
Input Types
Supported
Operating Temp
Y+
Humidity
Battery
Battery Life
Frequency
Y-
RF Modulation
Data Rate
Data Encoding
Z
Approvals
Device Powered Up
Device Has been Configured
Device TX or RX
Device Input Triggered
Value
Single EOL, Alarm+Tamper,
Dry Contact or Pulse Counting
(Clicker input)
-10°C to +49°C
0% - 93% Non-condensing
3V CR123A Lithium
Up to 5 years
433.42MHz
FSK
25kbps
Manchester
RCM (ANZ), CE (Europe)