5925 Heisley Road • Mentor, OH 44060-1833
WARNING
IF UNIT GETS TOO HOT OR WON'T SHUT OFF, DISCONNECT
POWER AT BRANCH PANEL. DO NOT UNPLUG CORD!
SIMPLE TROUBLE-SHOOTING CHART:
FAILURE
1. POWER LIGHT does NOT light
2. Unit does not heat or not heating properly 2a. Temperature control is set too low.
3. Unit gets too hot or won't shut off.
4. Blower does not work or makes noise
5. GFCI device trips
If the power supply cord is damaged, it must be replaced by the manufacturer, its service agent or similarly
qualified persons in order to avoid a hazard.
If cause is none of the above, refer to our list of Authorized Service Centers, FL-1400
MAINTENANCE INSTRUCTIONS
TROUBLE-SHOOTING GUIDE
POSSIBLE CAUSE
1a. Switch is "OFF"
1b. Cord is unplugged from wall outlet.
1c. Circuit breaker/fuse to wall outlet tripped/blown.
2b. Switch is "OFF".
2c. Doors are open too much.
2d. Gaskets are worn or torn.
2e. Thermometer not reading true temperature. Check cabinet
temperature with another thermometer.
3a. Defective thermostat or blower.
4a. Defective blower.
5a. Plug the cabinet into a non-GFCI outlet and set the
temperature control to its maximum. Let the cabinet run
for about 1 hour to dry out the heating element from any
moisture that may have been absorbed. After drying the
heating element, plug cabinet into the GFCI receptacle; the
cabinet should run properly. If the GFCI device continues
to trip, call the factory Authorized service agent.
FL-2344-DOM
Holding Cabinet
Rev. 4 (4/10)