Cres Cor H138NPSCLCMC5QRL 운영 및 유지보수 지침 매뉴얼 - 페이지 5

{카테고리_이름} Cres Cor H138NPSCLCMC5QRL에 대한 운영 및 유지보수 지침 매뉴얼을 온라인으로 검색하거나 PDF를 다운로드하세요. Cres Cor H138NPSCLCMC5QRL 9 페이지. Merchandising hot cabinets

Cres Cor H138NPSCLCMC5QRL 운영 및 유지보수 지침 매뉴얼
FL-2371-LC
Holding Cabinet
Rev. 3 (5/14)
Page 5 of 9
How to adjust/tighten the double door hinges:
1. Open the door 180°, lift it up and off. Lay it down
with the outside up.
2. Pop off hinge covers with a screwdriver.
3. Loosen the screws that hold hinges to the door.
Those holes are slotted for adjustment.
a) Push the hinge back for the door to close
easier; or
b) Pull the hinge forward to close the gap between
the door and the cabinet.
4. Tighten the screws and then test the door.
How to adjust /tighten the full door hinges:
1. Loosen the screws holding the hinge to the door.
2. Push or pull the hinge per instructions above.
FAILURE
1. POWER LIGHT (Yellow) does NOT light.
2. Unit does not heat.
3. Unit gets too hot or won't shut off.
4. Blower does not work or makes noise.
5. GFCI device trips.
GFCI (ground-fault circuit interrupter): A GFCI receptacle is a device that de-energizes a circuit when it detects an
unsafe flow of current to ground. The intention of a GFCI device is to minimize the potential for an electrical shock.
If cause is none of the above, refer to our list of Authorized Service Centers, FL-1400
MAINTENANCE INSTRUCTIONS
TROUBLE-SHOOTING GUIDE
5925 Heisley Road • Mentor, OH 44060-1833
Door
POSSIBLE CAUSE
1a. Switch is "OFF".
1b. Cord unplugged from wall outlet.
1c. Circuit breaker/fuse to wall outlet tripped/blown.
2a. Temperature control is set too low.
2b. Switch is "OFF".
3a. Defective electrical parts.
UNPLUG UNIT FROM WALL OUTLET.
4a. Defective blower.
5a. The insulation inside the heating element may have
absorbed some moisture. This may have occurred if
the cabinet has not been used for a long period of time
or during shipping and storage of the cabinet. Plug the
cabinet into a non-GFCI outlet and set the temperature
control to its maximum. Let the cabinet run for about 1
hour to dry out the heating element from any moisture may
have been absorbed. If the circuit breaker trips, call the
factory Authorized service agent. After drying the heating
element, plug cabinet into the GFCI receptacle; the cabinet
should run properly. If the GFCI device continues to trip,
call the factory Authorized service agent.
HINGE
ADJUSTMENT PLATE
HINGE COVER