Cres Cor RO151033 설치, 운영 및 유지보수 매뉴얼 - 페이지 8
{카테고리_이름} Cres Cor RO151033에 대한 설치, 운영 및 유지보수 매뉴얼을 온라인으로 검색하거나 PDF를 다운로드하세요. Cres Cor RO151033 11 페이지. 8kw rethermalizers
5925 Heisley Road • Mentor, OH 44060-1833
IF THE OVEN TURNS ON:
PROBLEM
Rethermalizer does not heat, or doesn't
heat properly
Blowers do not operate
Heater will not shut off
Vent fans do not shut off
Vent fans do not operate (See Note)
Control will not switch from "COOK" to
"HOLD" (timed mode)
Control will not switch from "COOK" to
"HOLD" (probe mode)
Control will not switch to "COOK" (probe
mode)
ERROR CODES:
CODE DISPLAYED
no p
Err0
NOTE: Vent fans will not operate until the control compartment requires ventilation to limit temperatures . Replacement
of electrical components must be done by a qualified electrician.
Refer to our Service Agency list, FL-1400 (found in the back of this manual), of authorized service centers .
Instructions for replacing parts are included in replacement parts list .
Call Toll-free: 877-CRES COR (273-7267) • Fax: 800-822-0393 • www.crescor.com
MAINTENANCE INSTRUCTIONS
TROUBLE-SHOOTING GUIDE (continued)
POSSIBLE CAUSE
1. Sensor
2. Heater contactor
3. Loose wiring at heater contactor
4. Retherm control
5. High Limit
1. Air retherm switch
2. Blower
3. Retherm control
1. Control defective
2. Heater contactor
1. Vent fan switch defective
2. Control compartment is still hot.
1. Vent fan switch defective
2. Vent fan defective
1. Unit is in "PROBE" mode.
2. Retherm control defective
1. Unit is in "TIMED" mode
2. Probe not plugged in
3. Probe defective
4. Retherm control defective
1. Unit is in "TIMED" mode
2. Probe temperature setting lower
than probe temperature
3. Probe not plugged in
4. Retherm control defective
CAUSE
No food probe
Temp probe bad
Rethermalizer
Rev. 3 (5/14)
SOLUTION
1. Replace
2. Replace
3. Replace
4. Replace
5. Replace
1. Replace
2. Replace
3. Replace
1. Replace
2. Replace
1. Replace
2. Wait until it cools
Check "Heater will not shut off"
1. Replace
2. Replace
1. Cancel recipe and switch to "TIMED" mode
2. Replace
1. Cancel recipe and switch to "PROBE" mode
2. Plug in probe
3. Replace
4. Replace
1. Switch to "PROBE" mode
2. Set probe temperature to desired tempera-
ture
3. Plug in probe
4. Replace
SOLUTION
Plug in probe
Replace
FL-RO151033
Page 8 of 11