ARCHPOT AWEIS 설치 및 운영 매뉴얼 - 페이지 7
{카테고리_이름} ARCHPOT AWEIS에 대한 설치 및 운영 매뉴얼을 온라인으로 검색하거나 PDF를 다운로드하세요. ARCHPOT AWEIS 12 페이지. Apf burner system
Figure 2
SWITCH
OPTIONAL SETUP: TIMER SWITCH
EMERGENCY SHUTOFF, REMOTE
CONTROL, POOL OPERATING
SYSTEM
Installation must conform with local codes or, in the absence of local codes, with the National Fuel Gas Code,
ANSI Z223.1 / NFPA 54, or International Fuel Gas Code. The appliance, when installed, must be electrically
grounded in accordance with local codes or, in the absence of local codes, with the National Electric Code,
Trouble Shooting
I installed the Electronic Ignition System, turned it on and nothing happened.
When this occurs it is usually due to an electrical wiring / power issue. Check all your electrical connections thor-
oughly to ensure all wires at the transformer and inside the fire feature are connected properly. If it appears all
wiring is connected properly, disconnect the wires at the fire feature, attach a Multimeter to the wires to confirm
a minimum of 24 volts when the fire feature is turned on. If you determine that you do not have a minimum of
24 volts at the fire feature conduct the same test at the transformer to ensure the transformer is in fact produc-
ing a minimum of 24 volts. If you do have a minimum of 24 volts at the fire feature contact us for further assis-
tance.
I installed the Electronic Ignition System, turned it on and I can see the glow plug glowing or-
ange and I can hear gas flowing but it will not ignite.
There are two possible causes to this problem; Air in the Gas Line or not enough Electrical Current to the fire
feature.
• Air in the Gas Line. If a new gas line was installed and the air was never purged from it prior to installing the
Electronic Ignition System then it may take several times of turning the fire feature on and off before the air is
purged from the gas line.
24V AC or 30V DC
TRANSFORMER
(SHOWN MOUNTED IN
ELECTRICAL BOX)
SUPPORT
PLATE
LEDGE
ANSI/NFPA 70, if applicable.
PILOT
ASSEMBLY
AWEIS
LOW VOLTAGE POWER
DRAIN
BURNER RING
FLEX LINES
MOUNTING BRACKET
NATURAL GAS SOURCE LINE
7
SUPPORT PLATE
KEY VALVE
ASSEMBLY