4 C h a n n e l D M X L E D D r iv e r - L D M X - P W M - 4
U s e r M a n u a l
5 .2 - 4 N o v e m b e r 2 0 1 6

Specifications

Physical

Inputs

Outputs

Installation

Connections

Figure 2 shows the connections on
the LDMX-PWM-4. For standard
operation, simply connect 24V to
the power connector, the led
fittings to the PWM outputs and
either the Colour Theme Controller
or a DMX source to control the light
levels.

Operation

The LDMX-PWM-4 has a single
24VDC power supply. Once it is connected, the red power LED shown in Figure 2 will come on. If the
unit is receiving good communications, the green DMX activity LED will also be on.

Setting Address

The DMX address is set using the first 9 switches of the DMX address switch. The address is set as a
binary number (with switch 1 the LSB, Appendix A lists addresses and their corresponding switch
settings). As the unit is a 3 channel receiver, it will respond to data in the set address, and the
following 2 addresses in the DMX data stream. Therefore, the address should not be set to over 510.
Note: that to use a Colour Theme Controller, the address must be set to 1.
Dimensions
Weight
Voltage
Current
Fuse
Communications
DMX Load
Outputs
Current Per Channel
Total Maximum Output
Figure 2 Connection diagram.
138 x 63 x 31
110
12 – 24
6
6.3
DMX or Colour Theme Controller
0.25
Standard Devices
3 Channels Common Anode (low side) PWM
3
6
DMX Address
1 2 3 4 5 6 7 8 9 10
Power
DMX
U n it s
mm
g
U n it s
VDC
A
A
U n it s
A
A
P a g e 3 o f 9