Cres Cor HC-UA-11 운영 및 유지보수 지침 매뉴얼 - 페이지 8

{카테고리_이름} Cres Cor HC-UA-11에 대한 운영 및 유지보수 지침 매뉴얼을 온라인으로 검색하거나 PDF를 다운로드하세요. Cres Cor HC-UA-11 12 페이지. Hot cabinets

Holding Cabinet
Rev. 4 (10/13)
Page 8 of 12
FAILURE
1 . Unit does not turn on (electric mode) .
2 . Unit does not turn on (gas mode) .
NOTE: The power cord can be left plugged in for a long period of time after the battery is fully charged . The
internal battery charger will safely "maintain" the battery .
3 . Unit heats up slowly .
4 . Unit does not heat (electric mode) .
5 . Unit does not heat (gas mode) .
NOTE: The control is equipped with an auto-ignite system . On startup and periodically throughout operation,
it will attempt to ignite the gas for 10 seconds . If it fails, the "reset" indicator will illuminate and an
audible alarm will sound, indicating no heat . If the tank is empty, this will usually happen within 20
seconds, in windy conditions, it could take up to 5 minutes for the alarm to become present . If this
happens, turn the power switch to "OFF" and then back to "GAS", and it will try to re-ignite .
6 . Unit gets too hot or won't shut off .
For repairs, refer to our list of Authorized Service Centers, FL-1400
NOTE: If any panel which is sealed with silicone needs to be removed for servicing by an authorized personnel,
the exterior seams need to be sealed with a food grade caulking material (certified against NSF/ANSI 51).
FL-2361
TROUBLE-SHOOTING
5925 Heisley Road • Mentor, OH 44060-1833
POSSIBLE CAUSE
1a . Power cord is not plugged in .
1b . Branch circuit breaker is tripped .
1c . Fuse is blown .
2a . Battery is low on charge . Plug power cord in for at
least an hour to charge battery (this time may vary
depending on state of battery) .
2b . Fuse is blown .
3a . Check operating instructions for preheat times .
3b. Defective electrical or gas components.
4a . Unit is not on .
4b . Thermostat is set too low .
4c. Defective electrical components.
5a . Unit is not on .
5b . Thermostat is set too low .
5c . Propane/gas tank has expired .
5d. A gust of wind may have blown out the flame or
prevented ignition of the gas.
5e. Defective electrical components.
6a. Defective electrical components.