Cres Cor 1000-CH-AL 설치 및 운영 매뉴얼 - 페이지 4
{카테고리_이름} Cres Cor 1000-CH-AL에 대한 설치 및 운영 매뉴얼을 온라인으로 검색하거나 PDF를 다운로드하세요. Cres Cor 1000-CH-AL 14 페이지. 1000-ch series radiant ovens
FL-2340
Ovens
Rev. 5 (7/08)
Page 4 of 14
INSTALLATION INSTRUCTIONS (continued)
HOW TO INSTALL CABINETS:
1.
Remove all packing material from the inside and all
vinyl from the outside of oven.
2.
Place the oven in a well ventilated area on level fl oor.
Clearance requirements: 3" (76mm) at the back, 2"
(51mm) at the top, 1" (25mm) at both sides.
3.
Install the pan slide racks on the sidewalls, if necessary.
4.
Slide drip pan(s) onto the bottom of the compartment(s).
5.
Remove (3) screws at the bottom front of the oven,
under the door (See Figure).
6.
Screw the drip tray bracket to the oven in those holes
and place the drip tray onto the bracket.
All models are rated at 208/240 Volts.
NOTE: OVENS NEED TO BE INSTALLED BY A
QUALIFIED PERSON.
Check the voltage selector switch which is under an access
cover on the back of the oven near the power cord.
Flip the switch "UP" for 208 Volts
Flip the switch "DOWN" for 240 Volts
MAKE SURE THE SWITCH POSITION MATCHES
YOUR POWER SOURCE.
Call Toll-free: 877-CRES COR (273-7267) • Fax: 800-822-0393 • www.crescor.com
5925 Heisley Road • Mentor, OH 44060-1833
DRIP TRAY
BRACKET
SCREWS