Hollow shaft display with serial output
Target Value
Value shown on the first line of the display which indicates the position which must be reached by manual
adjustment.
Backlash compensation value
If set different to zero, at each inversion of the rotation direction, the displayed value does not change until
the shaft completes a rotation which is equal to or above the backlash compensation value.
Set a positive value for backlash compensation in the forward direction and a negative value for
compensation in the reverse direction.
Tolerance around target value
When the actual value reaches inside the window around the target value (which is defined by the tolerance)
the red LED is turned off the green LED is turned on.
Example: with target value
Address device
This is the identification address of the unit, it must be unique for every device connected to the bus network,
acceptable values from 1 to 247.
Baud rate serial port communication
Parity bit
This constant sets the serial communication parity bit.
Adjustment of displayed value
After the installation of instrument on the machine and setting of all parameters, in order to visualize on the
display the correct value it is necessary to carry out the reset or preset.
Position the shaft in a position where the correct measurement that has to be visualized is known exactly (for
example the stroke end point) or measure the position in that position of the shaft. Program parameter
with value 3 in the first digit on the right and exit programming.
Now press O and
with O The display will now show the desired value.
If the required value is zero, instead of the preset function it is possible to use the reset function by setting 1
in the first digit on the right in the
Now that the instrument is adjusted, it is necessary to insert the desired
accidental reset/preset of the displayed value.
Date: 06/04/21
=50 and
=10, the green LED is on between 40,1 e 59,9.
VALUE
0
1
2
3
4
VALUE
0
1
2
will appear, press again 2 times O and set the correct value to display, then confirm
parameter so that pressing O will bring the displayed value to zero.
File: EP4RS_4.1_ing.doc
EP43RS / EP46RS
Baud rate
9600
19200
38400
57600
115200
Parity
even
odd
no parity, 2 stop bit