Cres Cor CO151X185B 설치, 운영 및 유지보수 매뉴얼 - 페이지 6

{카테고리_이름} Cres Cor CO151X185B에 대한 설치, 운영 및 유지보수 매뉴얼을 온라인으로 검색하거나 PDF를 다운로드하세요. Cres Cor CO151X185B 9 페이지. Convection and retherm ovens
Cres Cor CO151X185B에 대해서도 마찬가지입니다: 설치, 운영 및 유지보수 매뉴얼 (10 페이지), 설치, 운영 및 유지보수 매뉴얼 (12 페이지)

Cres Cor CO151X185B 설치, 운영 및 유지보수 매뉴얼
5925 Heisley Road • Mentor, OH 44060-1833
877/CRES COR (273-7267) • 440/350-1100
Fax: 440/350-7267 • www.crescor.com
PROBLEM
Cabinet does not heat, or
doesn't heat properly
Blowers do not operate
Heater will not shut off
Vent fan does not shut off
Vent fan does not operate
(See Note)
NOTE:
Vent fans will not operate until the control compartment requires ventilation to limit
temperatures. Replacement of electrical components must be done by a qualified electrician.
Refer to our Service Agency list, FL-1400 (found in the back of this manual), of authorized service
centers. Instructions for replacing parts are included in replacement parts list.
DESCRIPTION
Hot Unit, 120V, 1 Ph
Door Latch Kit
Latch Strike
Door Hinge
Door Assembly
Door Gasket
Interior
Casters
Casters w/brake
MAINTENANCE INSTRUCTIONS
TROUBLE-SHOOTING GUIDE,
POSSIBLE CAUSE
1. Thermostat
2. Heater relay
3. Loose wiring at heater relay
4. Hi-limit switch
5. On/Off switch
1. On/Off Switch
2. Blower
1. Thermostat
2. Relay
1. Vent fan switch
2. Control compartment still hot
1. Vent fan switch
2. Vent fan

REPLACEMENT PARTS:

Include all information on nameplate when ordering parts.
Cabinet Replacement Parts
Undercounter Ovens
Rev. 2 (2/05)
SOLUTION
1. Replace
2. Replace
3. Replace
4. Replace
5. Replace
1. Replace
2. Replace
1. Replace
2. Replace
1. Replace
2. Wait until it cools
Check "Heaters will not shutoff"
1. Replace
2. Replace
MODEL PREFIX CO-151
-XUA5B
HU675045
1006-120-01
1006-120-02
0519-074
1221-545
0861-250
0621-281
0569-310
0569-310B
FL-2290
6 of 9
Page
continued
-X185B
HU675046
1006-120-01
1006-120-02
0519-074
1221-546
0861-251
1104-107
0569-310
0569-310B