Cres Cor CO151XUA5B 설치, 운영 및 유지보수 매뉴얼 - 페이지 4

{카테고리_이름} Cres Cor CO151XUA5B에 대한 설치, 운영 및 유지보수 매뉴얼을 온라인으로 검색하거나 PDF를 다운로드하세요. Cres Cor CO151XUA5B 9 페이지. Convection and retherm ovens
Cres Cor CO151XUA5B에 대해서도 마찬가지입니다: 설치, 운영 및 유지보수 매뉴얼 (10 페이지), 설치, 운영 및 유지보수 매뉴얼 (12 페이지)

Cres Cor CO151XUA5B 설치, 운영 및 유지보수 매뉴얼
5925 Heisley Road • Mentor, OH 44060-1833
877/CRES COR (273-7267) • 440/350-1100
Fax: 440/350-7267 • www.crescor.com
HOW TO SET TIMER:
A. Press the UP arrow-button (on the Timer) to
increase the time. The longer the button is
held down, the faster the time will increase.
Pressing the DOWN arrow-button (using the
same method) will cause the time to
decrease.
B. Press START/STOP button on Timer to
begin cooking cycle. GREEN roast light will
light up. The timing light on the Timer will
flash. Timer will count down to 0.00.
C. Cooking time can be changed while oven is
in any mode.
(1) Press START/STOP button.
(2) Adjust time by using UP and DOWN
arrow-buttons.
(3) Press START/STOP button to restart
oven.
HOW TO START UNIT:
(for first-time operation only)
A new oven needs to "burn off" factory oils and
glue before it's first use. Do NOT load food into
oven until this has been done!
1. Push switch to "ON".
2. Set the COOK/RETHERM thermostat to
350°F/177°C.
3. Set the Hold thermostat to 150°F/66°C.
4. Set the timer to one (1) hour.
5. Allow oven to run automatically for one (1)
hour of COOK/RETHERM cycle and 30
minutes of Hold cycle.

OPERATING INSTRUCTIONS:

Undercounter Ovens
Rev. 2 (2/05)
HOW TO START UNIT:
(after first-time operation)
Push SWITCH to "ON".
For Automatic Operation:
1. Set COOK/RETHERM thermostat to the
cooking temperature you need.
2. Set Hold thermostat to the warming
temperature you need. Proper food holding
temperature is 140°F/60°C or higher.
3. Set Timer for the roasting time. The unit will
automatically switch to the pre-set "hold"
temperature after roasting time has expired.
For Holding Operation ONLY:
NOTES: For HOLD mode, preheat unit to
180°F/82°C for 60 minutes.
Cold food is NOT to be added when unit is
operating in HOLD mode.
1. Set HOLD thermostat to the temperature
you need.
2. Set timer at zero.
TO SHUT DOWN UNIT:
Push switch to "OFF".
CAUTION: Ventilating fans will continue to
run until the cabinet is cool. Do NOT
disconnect the power supply to the cabinet
while the ventilating fan is still operating.
FL-2290
4 of 9
Page