FIAMA P2X0T 빠른 시작 매뉴얼 - 페이지 2
{카테고리_이름} FIAMA P2X0T에 대한 빠른 시작 매뉴얼을 온라인으로 검색하거나 PDF를 다운로드하세요. FIAMA P2X0T 11 페이지. Positioner with analog output
Input description
The positioner is controlled by 4 opto-isolated inputs, that are:
START:
active from NA to NC, it causes the positioning start and brings different effects according to
the working mode (see working mode at page 4).
EMERGENCY: it must be normally closed, if open it blocks or interrupts the positioning
PIECECOUNTER: at the end of each positioning the instrument expects a changing over of the piece counter
input from NC to NA to proceed to the next positioning. NB: if not used connect it in parallel
with the
PRESET:
the changing over from NA to NC causes the reset or the preset loading according to the
zero reset procedure constant (see zero reset procedure page 6).
For switches see the connections scheme at page 10.
Output descriptions
The positioner is able to manage 3 relays outputs:
START/STOP:
FORWARD/BACKWARD:
END POSITIONING:
ANALOG OUTPUT
For switches see the connections scheme at page 10
PROGRAMMING
The following keys are used to programme:
PGM
to start and to leave the programming mode of the instrument
to change from one constant to another or to increase the digit value during modification
or to change from one digit to the next one
to confirm inserted values
RESET/ENTER
To enter programming mode is necessary to press the PGM key ; on the display you will see the
write
(immediate positioning); by the key
(cycles),
to insert an immediate positioning dimension (see next paragraph)
to insert dimensions and positioning programs, number of pieces and cycles (see next
paragraph)
per impostare il numero di cicli del programma di posizionamento da eseguire (vedi
"Impostazione del numero di cicli" a pagina 4)
to enter the machinery constants of the positioner (see Setting up of Machinery Constants
at page 4)
to change to manual operating mode of positioner (see Manual Operating mode at page 7)
to test inputs and outputs (see Test function at page 7)
data: 13/01/16
input.
START
normally open switch that closes to allow positioning
change-over switch that controls the direction of motion of the positioned axis
normally open switch that closes at positioning end
voltage selectable 0÷10V or –10÷10V, and current 4-20mA
(costanti),
(manual),
File: P2XT_smd_ing.doc
you can run through the menus
(test) whose functions are the following:
(quote),
pag 2 di 10