• Preset Dimension
The instrument enables you to set the value that will be visualised when the RESET/ENTER key is pressed or
the PRESET input is activated, according to the zeroset mode you have chosen (see next paragraph).
• Zeroset Modes
By setting the Zeroset Mode you can determine the effect you will obtain by pressing the RESET/ENTER key
for about 3 seconds or the effect of the PRESET input.
Chose the required Zeroset mode from the following table.
Zero set
mode
0
1
2
3
4
5
6
7
8
Dimensions protected by password
To prevent accidental or undesired alteration of positioning dimensions, the instrument offers you the
possibility to protect access to dimensions by mean of passwords. Therefore options are S for protected
dimensions and N for unprotected dimensions.
Time constant for acceleration ramp
Starting the positioning axis, before reaching the maximum speed, the positioner produces an acceleration
ramp with a time constant that may be set-up between 50 to 9999 milliseconds.
Time constant for deceleration ramp
During the positiong, reached the Slow value, by the passing from the speed Fast to the speed Slow, it
produces a decelaration ramp with a time constant that may be set-up between 50 and 9999 milliseconds.
Value of the analog output for the speed Fast
The output value which corresponds to the speed Fast is stated in per cent of the maximum value and that can
be set-up from 1% to 100%.
Value of the analog output for the speed Slow
The output value which corresponds to the speed Slow is stated in per cent of the maximum value and that
can be set-up from 1% to 100%.
Working way for output -10/+10V o 0/10V
Through this constant is possible to select the type of output: setting 0 (driving gear) the output goes from -10V
to +10V, positive voltage for the onward gear and negativ for the backward gear, setting 1 (inverter) the output
goes from 0 to +10V and the gear wise is discriminated by the relay of Forward/Backward.
By using the current output 4/20 mA set this constant to 1.
• Dimensions lower limit
Due to safety reasons the positioner prevents the entry of dimensions lower than the value set in this constant.
Set a value lower then the minimum value of positioning dimensions
data: 13/01/16
effect of PRESET input
RESET
PRESET
RESET
RESET
PRESET
PRESET
INPUT DISABLED
INPUT DISABLED
INPUT DISABLED
File: P2XT_smd_ing.doc
Effect by pressing
RESET/ENTER key for 3
seconds
KEY DISABLED
KEY DISABLED
RESET
PRESET
RESET
PRESET
RESET
PRESET
KEY DISABLED