ATTENTION! Do not use the machine before you have read and understood the Instructions for use manual
The machine
doesn't work
as it should?
The suction
doesn't work
as it should?
The machine
doesn't clean
as it should?
The brushes
don't work as
they should?
1 Check battery charge gauge.
1 Check if the suction hose is
correctly installed and cleaned.
1 Check if you have the right water
settings.
1 Remove side skirt assembly and
verify brush installation and
condition
2 E -stop icon that appears on display
when E-stop switch is engaged.
Twist E-stop switch to enable
machine function
2 Inspect recovery tank float switch
operation
2 Check if the solution tap is open.
2 Press "I" scroll down to faults and
press ">" button to view faults
3 Check battery cables are well
connected together.
3 Check if squeegee blades are
damaged or dirty.
3 Check if the solution filter is
cleaned.
3 Check if there are external materials
avoiding brush rotating.
www.crescentindustrial.co.uk
SC6000
4 Recovery tank seal cover must
correctly installed and in good
condition.
4 Close the recovery tank cover prop -
erly and/or verify the gasket wear.