Cisco 5509 - Catalyst Chassis Switch 빠른 설치 매뉴얼 - 페이지 15

{카테고리_이름} Cisco 5509 - Catalyst Chassis Switch에 대한 빠른 설치 매뉴얼을 온라인으로 검색하거나 PDF를 다운로드하세요. Cisco 5509 - Catalyst Chassis Switch 17 페이지. Wireless controller
Cisco 5509 - Catalyst Chassis Switch에 대해서도 마찬가지입니다: 설치 매뉴얼 (34 페이지)

Cisco 5509 - Catalyst Chassis Switch 빠른 설치 매뉴얼
B
Inserting and Removing Power Supplies (cont.)
Removing a power supply from the chassis
AC power supplies
1
Turn OFF (0) the power switch. Disconnect the power cord from the power source and
from the power supply.
2
Use a flat-blade screwdriver to loosen the captive installation screw.
3
Grasp the power supply handle and pull the supply straight out of the bay, supporting the
supply with your other hand (see figure). Install a filler plate if the bay is to remain empty.
DC power supplies
1
Turn OFF (0) the power switch on the power supply.
2
Turn off the power to the DC circuit connected to the power supply.
3
Remove the terminal block cover from the power supply. Disconnect the DC-input wires
from the terminal block. Disconnect the ground wire last.
4
Disconnect the central office (CO) ground from the CO ground connector.
5
Use a flat-blade screwdriver to loosen the captive screw on the power supply.
6
Grasp the power supply handle and pull the supply straight out of the bay, supporting the
supply with your other hand (see figure). Install a filler plate if the bay is to remain empty.
DS3
DS3
DS3
UTP
UTP
UTP
o
o
AC
FAN
OUTPUT
OK
OK
FAIL
AC
FAN
OUTPUT
OK
OK
FAIL
15