Cisco 6500 - Catalyst Series 10 Gigabit EN Interface Module Expansion에 대해서도 마찬가지입니다: 설치 참고 사항 (14 페이지), 솔루션 매뉴얼 (17 페이지), 설치 참고 사항 (46 페이지), 설명 (1 페이지), 제품 게시판 (6 페이지), 공지 사항 (4 페이지), 데이터시트 (9 페이지), 데이터시트 (18 페이지), 백서 (18 페이지), 구성 매뉴얼 (8 페이지), 설치 참고 사항 (28 페이지), 문제 해결 매뉴얼 (11 페이지), 설치 참고 사항 (18 페이지), 사용자 설명서 (17 페이지), 설치 참고 사항 (24 페이지), 매뉴얼 (19 페이지), 설치 참고 사항 (36 페이지)

Cisco 6500 - Catalyst Series 10 Gigabit EN Interface Module Expansion 백서
SRM and IP Multicast
With SRM, the VLAN interfaces on the nondesignated router are in a down state. Even after a failover, these interfaces will
not move into an up state until the supervisor engine verifies that the VLAN has at least one connected physical interface in
the forwarding state. This interruption causes the supervisor engine to delete all multicast entries in the PFCx and this disrupts
multicast forwarding. As an enhancement to the original SRM implementation, Cisco Catalyst OS release 7.1 provides
support for IP Multicast stateful redundancy. When SRM is enabled in Cisco Catalyst OS version 7.1, the multicast flows are
preserved during a failover.
Supervisor and MSFC Failover Tests
A test environment was created to demonstrate sample high-availability switchover scenarios and record the corresponding
failover times. The test setup included one Cisco Catalyst 6509 chassis with dual supervisor engine 2 line cards running Cisco
Catalyst OS version 7.2.2 or MSFC2 hardware running Cisco IOS Software Release 12.1(11b)E4. These tests were intended
to be basic and easily demonstrated. The testing mechanism was pings between two end devices connected directly to the
switch. Spanning-Tree was enabled on the ports in use for all scenarios. Tests were initiated by resetting the switch supervisor
engine. Each scenario was tested eight times and the results were averaged.
Layer 2 Failover
For Layer 2 traffic between two end stations within the same VLAN , the failover resulted in a one or two ping timeout
(approximately one- or two-second failover time).
Note: This test can be performed on a supervisor engine without an MSFC.
Layer 3 Failover
For Layer 3 traffic, a common test environment was created for measuring the supervisor or MSFC failover of a single Cisco
Catalyst 6500 Series configured first with DRM and then with SRM. The two pinging devices were placed in separate VLANs.
The basic software configuration included enabling the High Availability feature on the Cisco Catalyst OS and then either
DRM or SRM redundancy in the Cisco IOS Software on the MSFC2. The complete configurations are shown below.
SRM
hostname SRM
!
redundancy
high-availability
single-router-mode
!
interface Vlan20
ip address 10.20.1.3 255.255.255.0
no ip redirects
!
interface Vlan30
ip address 10.30.1.3 255.255.255.0
no ip redirects
!
end
All contents are Copyright © 1992–2002 Cisco Systems, Inc. All rights reserved. Important Notices and Privacy Statement.
Cisco Systems, Inc.
Page 16 of 19