Cisco AJ732A - MDS 9134 Fabric Switch 릴리스 노트 - 페이지 36

{카테고리_이름} Cisco AJ732A - MDS 9134 Fabric Switch에 대한 릴리스 노트을 온라인으로 검색하거나 PDF를 다운로드하세요. Cisco AJ732A - MDS 9134 Fabric Switch 44 페이지. Converged network switches for nx-os 4.0(1a)n1(1)
Cisco AJ732A - MDS 9134 Fabric Switch에 대해서도 마찬가지입니다: 구성 매뉴얼 (49 페이지), 릴리스 노트 (48 페이지), 릴리스 노트 (44 페이지), 릴리스 노트 (36 페이지), 릴리스 노트 (26 페이지), 릴리스 노트 (22 페이지), 빠른 참조 매뉴얼 (14 페이지), 릴리스 노트 (3 페이지)

Cisco AJ732A -  MDS 9134 Fabric Switch 릴리스 노트
Caveats
S e n d d o c u m e n t a t i o n c o m m e n t s t o m d s f e e d b a c k - d o c @ c i s c o . c o m
All known resource leaks in the CIM Server have been fixed. However, some growth in the process
size can still be observed when repeatedly executing queries that retrieve large amounts of data.
CSCsi07649
Symptom: When using the Fcanalyzer on an MDS 9513 Switch or an MDS 9124 Switch to capture
packets remotely, no packets were captured.
Workaround: This issue is resolved.
CSCsi51436
Symptom: Following a fabric reconfiguration, if you use Fabric Manager Server to discover the
fabric and you check the Accelerate Discovery check box on the Discover New Fabric dialog box,
some VSANs are segmented by Fabric Manager Server. VSANs may be segmented because they are
isolated or down.
Workaround: This issue is resolved.
CSCsi56949
Symptom: When creating a new VSAN through Fabric Manager or through a script that can create a
VSAN on each switch at the same time, the same domain ID is created for each switch. This causes the
newly-created VSAN to be segmented on all links.
Workaround: This issue is resolved.
CSCsj13175
Symptom: A fibre channel port on an MDS switching module remained out-of-service after the port
was put back in service. As a result, it was not possible to configure the port.
Workaround: This issue is resolved.
CSCsj29134
Symptom: Following a Cisco SAN-OS software upgrade or downgrade, certain ports get stuck in
link failure or in a not-connected state, even though the same SFP, cable, host, or storage device
works in other ports on the same module.
Workaround: This issue is resolved.
CSCsj50299
Symptom: Following an upgrade to Cisco SAN-OS Release 3.1(3a), the SSH server stopped
working.
Workaround: This issue is resolved.
CSCsj52389
Symptom: When an fcalias is added as a zone member or a zone is added to a zone set via SNMP,
there is an SNMPD memory leak.
Workaround: This issue is resolved.
CSCsj95379
Symptom: A data path processor (DPP) might fail on an MDS switch running Cisco SAN-OS
Release 3.1(2b) with an SSM running SSI Release 3.1(2m) and with the SANTap feature
provisioned. The failure occurs while the DPP is processing an unexpected transfer ready message.
Workaround: This issue is resolved.
CSCsh63896
Symptom: After switching over from the active to the standby supervisor, an EMC call home
message displays that says the mgmt0 interface has failed on slot 1.
Cisco MDS 9000 Family Release Notes for Cisco MDS SAN-OS Release 3.2(1)
36
OL-14116-01