CSCso28570
Symptom: On the MDS 9222i module, an upgrade from SAN-OS Release 3.2(x) to Release 3.3(1a)
fails when there is an active FC-Redirect configuration (created by Cisco SME or Cisco DMM
applications) on the switch. An active FC-Redirect configuration is defined as:
If an upgrade is attempted when such active configuration is present, the switch will go into a
disruptive upgrade.
Workaround: This issue is resolved.
CSCso41087
Symptom: If FCIP is enabled and the SAN-OS is upgraded, the SNMP service will run into
exception and the following syslog message is displayed:
setting error index
Workaround: This issue is resolved.
CSCsq29607
Symptom: After logging back into Fabric Manager Client, clicking on the Summary tab causes a
disconnect.
Workaround: This issue is resolved..
CSCsq44360
Symptom: When the startup rising alarm is triggered, the sample value is smaller than the rising
threshold. This should not trigger an alarm.
Workaround: This issue is resolved.
CSCsr22782
Symptom: On Solaris 8, 9, and 10 and RedHat Linux AS4 (kernel version 2.6) the Fabric Manager
Release 3.4(1) installer displays a warning message indicating that it is an unsupported platform.
This occurs even though these platforms are supported.
Workaround: This issue is resolved.
CSCsr89410
Symptom: An FCIP link may flap due to a watchdog timeout condition when FCIP Tape
Acceleration is running inSAN-OS Release 3.3(1c).
Workaround: This issue is resolved.
CSCsr92585
Symptom: An FCIP link running with Tape Acceleration may flap when the host is attempting
SRR/REC tape error handling.
Workaround: This issue is resolved.
CSCsw95386
Symptom: Certain applications that use SME perform a move medium operation to change tapes
in a library, without first performing a load or unload operation. This causes the check condition
"SCSI check condition of medium may have changed." SME does not perform the media
identification logic correctly for this check condition, which causes tape labeling to fail
Workaround: This issue is resolved.
OL-14116-11
FC-Redirect configuration for hosts or target connected locally
FC-Redirect configuration created by application running on that switch.
.
Cisco MDS 9000 Family Release Notes for Cisco MDS SAN-OS Release 3.3(3)
SNMP Operation(165) failed (62)
Caveats