AccuStream Cutting Systems
4.2 Mounting Collar
Mounting Collar Installation
The AccuValve is normally mounted with the mounting collar assembly 11198 (shown below) using the
¼" HP inlet connection. The Thimble Filter comes standard with the Dialine assembly. This filter can
be purchased separately. Other mounting options are also available.
1. To install the mounting collar, transfer, drill and tap two 5/16-18UNC holes into the Z-axis
faceplate.
NOTE: For proper alignment, the mounting holes must be 1.625 in. (41.275 mm) from center
of holes apart. See illustration (above).
2. With the adapter and seat removed from the valve body, slide the valve body down into the
collar and align the high-pressure water inlet hole with the collar.
13084 ON/OFF VALVE & CUTTING HEAD MANUAL
6