Cisco Catalyst 2900 Series 하드웨어 설치 매뉴얼 - 페이지 15
{카테고리_이름} Cisco Catalyst 2900 Series에 대한 하드웨어 설치 매뉴얼을 온라인으로 검색하거나 PDF를 다운로드하세요. Cisco Catalyst 2900 Series 47 페이지. Xl modules
Cisco Catalyst 2900 Series에 대해서도 마찬가지입니다: 매뉴얼 (19 페이지)
Chapter 1
Overview
Note
100BaseFX Modules
1000BaseX Modules
Table 1-4
GBIC Cable Specifications
GBIC
Shortwave (SX)
78-5912-03
The 10/100 ports are numbered 1X through 4X. The X indicates that the pins on
the port connector are internally crossed. If you are connecting to a device with
ports marked with an X, such as another switch or hub, use a crossover cable. If
you are connecting to devices with ports not marked with an X, such as a PC,
workstation, or server, use a straight-through cable.
For the connector pinouts and schematics, see the section "10/100 Module
Cabling" in Appendix B, "Connectors and Cables."
Always observe the following general rules when connecting
devices: Use a straight-through cable to connect two ports when one
is designated with an X; use a crossover cable to connect two ports
when both are designated with an X.
The 100BaseFX ports use 50/125- or 62.5/125-micron multimode fiber-optic
cabling with duplex SC connectors. When set to run in full-duplex mode,
100BaseFX module ports can connect to compatible devices over distances of up
to 2 kilometers. For connector and schematic information, see Appendix B,
"Connectors and Cables."
GBICs require the following fiber-optic cables with duplex SC connectors.
Wavelength (nm)
850
Catalyst 2900 Series XL Modules Hardware Installation Guide
Core Size
Fiber Type
(micron)
MMF
62.5
62.5
50.0
50.0
Cabling Guidelines
Modal
Bandwidth
Cable Distance
(MHz.km)
Maximum
160
722 ft (220 m)
200
902 ft (275 m)
400
1640 ft (500 m)
500
1804 ft (550 m)
1-9