Plastic Disk Mounting
The transducer may be attached to plate glass windows or other smooth surfaces using the plastic-
mounting disk. The glass must be firmly mounted to avoid vibration.
la. For temporary mounting, use double-stick tape and press the disk firmly to the clean and dry
surface. (Figure 5)
1b. For permanent mounting, discard the double-stick tape and use a small amount of clear silicone
exterior caulking compound. Place a small thin layer across the disk and press firmly and evenly to
minimize air bubbles. This method provides better coupling for high frequency response. Allow the
adhesive to set as recommend by the manufacturer (usually 24 hours). (figure 6A)
2.
Screw the Transducer clockwise onto the plastic disc until firm. DO NOT TIGHTEN
EXCESSIVELY. (figure 6B)
Attention: Be sure not to over tighten the transducer, the plastic insert may be damaged
Figure 4
Figure 5
Figure 6