FIBARO FGDW-002 운영 매뉴얼 - 페이지 13
{카테고리_이름} FIBARO FGDW-002에 대한 운영 매뉴얼을 온라인으로 검색하거나 PDF를 다운로드하세요. FIBARO FGDW-002 16 페이지. Door/window sensor
FIBARO FGDW-002에 대해서도 마찬가지입니다: 운영 매뉴얼 (16 페이지)
53. Temperature offset
The value to be added to the actual temperature, measured by the sen-
sor (temperature compensation).
Available settings: -1000–1000 (-100–100°C, 0.1°C step)
Default setting:
54. Temperature alarm reports
Temperature alarms reported to the Z-Wave controller. Thresholds are
set in parameters 55 and 56.
Available settings: 0 - temperature alarms disabled
Default setting:
55. High temperature alarm threshold
If temperature is higher than set value, overheat notification will be
sent and high temperature scene will be triggered (if activated).
Available settings: 1-600 (0.1-60°C, 0.1°C step)
Default setting:
56. Low temperature alarm threshold
If temperature is lower than the set value, underheat notification will
be sent and low temperature scene will be triggered (if activated).
Available settings: 0-599 (0-59.9°C, 0.1°C step)
Default setting:
0 (0°C )
Parameter size:
1 - high temperature alarm
2 - low temperature alarm
3 - high and low temperature alarms enabled
0
Parameter size:
350 (35°)
Parameter size:
100 (10°)
Parameter size:
2 [bytes]
1 [byte]
2 [bytes]
2 [bytes]
ADVAnCED PARAMETERS
13