#3: Installation
Connecting the Single Switch in a manner inconsistent
!
with this manual may cause risk to health, life or material
damage.
When connecting the Single Switch act in accordance with the
following rules:
•
Connect only in accordance with one of the diagrams,
•
Electrical installation must be protected by overcurrent protection
(fuse) of with a value not higher than 10A,
•
The Single Switch should be installed in a wall switch box compliant
with a relevant national safety standards and with depth no less
than 60mm,
•
Electrical switches used in installation should be compliant with the
relevant safety standards,
•
length of wires used to connect the control switch should not
exceed 10m.
Notes for the diagrams:
S1 - terminal for 1st switch
S2 - terminal for 2nd switch
S1 S2 L
L
Q
N
B
L - terminal for live lead
Q - output terminal of the 1st channel
N - terminal for neutral lead
B - service button