#8: Advanced parameters
The Motion Sensor allows to customize its operation to user's needs.
The settings are available in the FIBARO interface as simple options
that may be chosen by selecting the appropriate box.
In order to configure the Motion Sensor (using the home Center con-
troller):
1. Go to the device options by clicking the icon:
2. Select the „Advanced" tab.
Wake up interval
Available settings: 1-65535 (1-65535 seconds)
Default setting: 7200 (every 2 hours)
The Motion Sensor will wake up after each defined time interval and
always try to connect with the main controller. After a successful com-
munication attempt, the sensor will update configuration parame-
ters, associations and settings and will go into standby mode. After
failed communication attempt (e.g. lack of Z-Wave range) the device
will go into standby mode and retry to establish connection with the
main controller after the next time interval.
Wake up may be performed manually by a single B-button click.
Longer time interval means less frequent communication and thus a
longer battery life.
1. Motion detection - sensitivity
The lower the value, the more sensitive the PIR sensor is.
Available settings: 8-255
Default setting:
2. Motion detection - blind time
PIR sensor is "blind" (insensitive) to motion after last detection for the
amount of time specified in this parameter.
Shorter time periods allow to detect motion more frequently, but the
battery will be drained faster.
Available settings: 0-15 (0.5-8 seconds, time [s] = 0.5 x (value+1))
Default setting:
15
Parameter size:
15
Parameter size:
2 [bytes]
1 [byte]
ADvAnCED PARAMETERS
11
i
NOTE
Blind time should be
shorter that the time
period set in parame-
ter 6 (alarm cancella-
tion delay).