Setting
0
1
2
4
8
16
Parameter 26: The function of 3-way switch
Switch no. 2 controls the Dimmer 2 additionally (in 3-way switch mode).Function disabled for parameter 20 set to 2 (roller blind switch).
Size: 1 Byte, Default Value: 0
Setting
0
1
Parameter 27: Associations in Z-Wave network security mode
This parameter defines how commands are sent in specified associationgroups: as secure or non-secure. Parameter is active only inZ-Wave network security
mode. It does not apply to 1st Lifeline group.
NOTE: Parameter 27 values may be combined, e.g. 1+2=3 means that 2nd & 3rd group are sent as secure.
Size: 1 Byte, Default Value: 15
Setting
0
1
2
4
8
15
Parameter 28: Scene activation functionality
SCENE ID depends on the switch type configurations
NOTE: Enabling scene activation functionality may cause slight delay in response to externalswitches and sending associations.
Size: 1 Byte, Default Value: 0
Setting
0
1
Parameter 29: Switch functionality of S1 and S2
This parameter allows for switching the role of keys connected to S1 and S2 without changes in connection.
Size: 1 Byte, Default Value: 0
Setting
0
1
Parameter 30: Load control mode
This parameter allows to set the desired load control mode. The device automatically adjusts correct control mode, but the installer may force its change using this
parameter.
Size: 1 Byte, Default Value: 2
Setting
0
1
2
Parameter 31: Load control mode recognized during auto-calibration
Size: 1 Byte, Default Value: 0
https://manual.zwave.eu/backend/make.php?lang=en&sku=FIBEFGD-212
https://manual.zwave.eu/backend/make.php?lang=en&sku=FIBEFGD-212
Description
all actions send to association groups;
do not send when switching on the Dimmer (single click)
do not send when switching off the Dimmer (single click)
do not send when changing dimming level (holding and releasing)
do not send on double click
send 0xFF value on double click
Description
3-way switch function for S2 disabled
3-way switch function for S2 enabled
Description
all groups (II-V) sent as non-secure
group 2 sent as secure
group 3 sent as secure
group 4 sent as secure
group 5 sent as secure
groups (II-V) sent as secure
Description
functionality deactivated;
functionality activated.
Description
standard mode;
S1 operates as S2, S2 operates as S1.
Description
forced leading edge control
forced trailing edge control
control mode selected automatically (based on auto-calibration).
9/14