encryption.- Works as Z-Wave signal repeater (all non-battery operated devices within the network will act as repeaters to increase reliability of the network).- May
be used with all devices certified with the Z-Wave Plus certificate and should be compatible with such devices produced by other manufacturers.
Prepare for Installation / Reset
Please read the user manual before installing the product.
In order to include (add) a Z-Wave device to a network it must be in factory default state. Please make sure to reset the device into factory default. You can do
this by performing an Exclusion operation as described below in the manual. Every Z-Wave controller is able to perform this operation however it is recommended
to use the primary controller of the previous network to make sure the very device is excluded properly from this network.
Reset to factory default
This device also allows to be reset without any involvement of a Z-Wave controller. This procedure should only be used when the primary controller is inoperable.
1.Quickly, three times click, then press and hold one of the buttons to enter menu.
2.Release the button when the device glows yellow.
3.Quickly click the button to confirm.
4.After a few seconds, the device will be restarted, which is signaled with the red LED color.
Safety Warning for Mains Powered Devices
ATTENTION: only authorized technicians under consideration of the country-specific installation guidelines/norms may do works with mains power. Prior to the
assembly of the product, the voltage network has to be switched off and ensured against re-switching.
Installation
Notes for diagrams:
N - terminal for neutral wire
S - support terminal of 2-wire connection
L - terminal for live wire
Q - output terminal for controlled load
G - groove used to measure wire length
Preparing for installation
Prepare wires by removing 12-12.5mm of insulation from their ends. You can use groove on the side of the unit to measure the length.
When installing with FIBARO or GIRA covers:
1. Pull out the switch button.
2. Take off the cover plate.
When installing with Legrand or Schneider covers:
1. Pull out the original switch button.
2. Take off the original cover plate.
3. Dismount the original mounting frame.
4. Snap the new mounting frame.
Electrical connection
1. Switch off the mains voltage (disable the fuse).
2. Connect with one of the diagrams below:
3. Verify correctness of connection.
4. Tighten the terminal screws using PH1 screwdriver.
Diagram 1: Example connection for 3-wire installation
Diagram 2: Example connection for 3-wire installation with Bypass 2
manual.zwave.eu/backend/make.php?lang=en&sku=FIBEFGWDEU-111