Sharp Carousel R-1600 서비스 매뉴얼 - 페이지 9
{카테고리_이름} Sharp Carousel R-1600에 대한 서비스 매뉴얼을 온라인으로 검색하거나 PDF를 다운로드하세요. Sharp Carousel R-1600 48 페이지. Over the range microwave oven
Sharp Carousel R-1600에 대해서도 마찬가지입니다: 운영 매뉴얼 (28 페이지)
The following is a description of component functions during
oven operation.
OFF CONDITION
Closing the door activates the door sensing switch and
secondary interlock switch. (In this condition, the monitor
switch contacts are opened.)
When oven is plugged in, 120 volts A.C. is supplied to the
control unit. (Figure O-1).
1. The display will show "SHARP SIMPLY THE BEST
PRESS CLEAR AND PRESS CLOCK".
To set any program or set the clock, you must first touch
the STOP/CLEAR pad. The display will clear, and " : "
will appear .
COOKING CONDITION
Program desired cooking time touching the NUMBER pads.
When the START pad is touched, the following operations
occur:
1. The contacts of relays are closed and components
connected to the relays are turned on as follows.
(For details, refer to Figure O-2)
RELAY
CONNECTED COMPONENTS
RY1
Oven lamp / Fan motor / Stirrer motor
RY2
Power transformer
RY3
Turntable motor
RY4
Hood fan motor
2. 120 volts A.C. is supplied to the primary winding of the
power transformer and is converted to about 3.3 volts
A.C. output on the filament winding, and approximately
2000 volts A.C. on the high voltage winding.
3. The filament winding voltage heats the magnetron
filament and the H.V. winding voltage is sent to a voltage
doubler circuit.
4. The microwave energy produced by the magnetron is
channelled through the waveguide into the cavity feed-
box, and then into the cavity where the food is placed to
be cooked.
5. Upon completion of the cooking time, the power
transformer, oven lamp, etc. are turned off, and the
generation of microwave energy is stopped. The oven
will revert to the OFF condition.
6. When the door is opened during a cook cycle, monitor
switch, door sensing switch, secondary interlock switch
and primary interlock relay are activated with the following
results. The circuits to the stirrer motor, the cooling fan
motor, the turntable motor, and the high voltage
components are de-energized, and the digital read-out
displays the time still remaining in the cook cycle when
the door was opened.
7. The monitor switch is electrically monitoring the operation
OPERATION
DESCRIPTION OF OPERATING SEQUENCE
of the secondary interlock switch and primary interlock
relay (RY2) and is mechanically associated with the door
so that it will function in the following sequence.
(1) When the door opens from a closed position, the
primary interlock relay and secondary interlock switch
open their contacts, and then the monitor switch
contacts close.
(2) When the door is closed from the open position, the
monitor switch contacts first open, and then the
contacts of the secondary interlock switch and door
sensing switch close.
If the secondary interlock switch and primary interlock relay
(RY2) fail with their contacts closed when the door is
opened, the closing of the monitor switch contacts will form
a short circuit through the monitor fuse, secondary interlock
switch and primary interlock relay (RY2), causing the moni-
tor fuse to blow.
POWER LEVEL P-0 TO P-90 COOKING
When Variable Cooking Power is programmed, the 120
volts A.C. is supplied to the power transformer intermittently
through the contacts of relay (RY2) which is operated by the
control unit within an interval second time base. Microwave
power operation is as follows:
VARI-MODE
ON TIME
Power 10(P-HI)
(100% power)
Power 9(P-90)
(approx. 90% power)
Power 8(P-80)
(approx. 80% power)
Power 7(P-70)
(approx. 70% power)
Power 6(P-60)
(approx. 60% power)
Power 5(P-50)
(approx. 50% power)
Power 4(P-40)
(approx. 40% power)
Power 3(P-30)
(approx. 30% power)
Power 2(P-20)
(approx. 20% power)
Power 1(P-10)
(approx. 10% power)
Power 0(P-0)
(0% power)
Note: The ON/OFF time ratio does not correspond with
the percentage of microwave power, because
approx. 2 seconds are needed for heating of the
magnetron filament.
7
OFF TIME
32 sec.
0 sec.
30 sec.
2 sec.
26 sec.
6 sec.
24 sec.
8 sec.
22 sec.
10 sec.
18 sec.
14 sec.
16 sec.
16 sec.
12 sec.
20 sec.
8 sec.
24 sec.
6 sec.
26 sec.
0 sec.
32 sec.
R-1600
R-1601
R-1602