R-1601
R-1602
LSI(IZA958DR)
The I/O signal of the LSI(IZA958DR) is detailed in the following table.
Pin No.
Signal
1
AN10
2
AN11
3
AVSS
4
P10
OUT
5
P11
OUT
6
P12
OUT
7
P13
OUT
8
P14
OUT
9-10
P15-P16
OUT
11
P17
OUT
12
X1
13
X2
OUT
14
VSS
15
OSC2
OUT
16
OSC1
17
TEST
18
RES
19
P20
OUT
20-22
P21-P23
OUT
23
P24
OUT

DESCRIPTION OF LSI

I/O
IN
Signal coming from touch key.
When either G10 line on key matrix is touched, a corresponding signal out of P10, P11, P12,
P13, P14 and P17 will be input into AN10. When no key is touched, the signal is held at "H" level.
IN
Signal similar to AN10.
When either G9 line on key matrix is touched, a corresponding signal will be input into AN11.
IN
Connected to VC.
Key strobe signal.
Signal applied to touch-key section. A pulse signal is input to AN9, AN10, AN11, P41 and
P42 terminal while one of G8 line keys on key matrix is touched.
Key strobe signal.
Signal applied to touch-key section. A pulse signal is input to AN9, AN10, AN11, P41 and
P42 terminal while one of G7 line keys on key matrix is touched.
Key strobe signal.
Signal applied to touch-key section. A pulse signal is input to AN9, AN10, AN11, P41 and
P42 terminal while one of G6 line keys on key matrix is touched.
Key strobe signal.
Signal applied to touch-key section. A pulse signal is input to AN9, AN10, AN11, P41 and
P42 terminal while one of G5 line keys on key matrix is touched.
Key strobe signal.
Signal applied to touch-key section. A pulse signal is input to AN9, AN10, AN11, P41 and
P42 terminal while one of G4 line keys on key matrix is touched.
Terminal not used.
Key strobe signal.
Signal applied to touch-key section. A pulse signal is input to AN8, AN9, AN10, AN11, P41
and P42 terminal while one of G1 line keys on key matrix is touched.
IN
Connected to GND.
Terminal not used.
IN
Power source voltage:-5V.
VC voltage of power source circuit input.
Internal clock oscillation frequency control output.
Output to control oscillation input of OSC2.
IN
Internal clock oscillation frequency input setting.
The internal clock frequency is set by inserting the ceramic filter oscillation circuit with respect
to OSC1 terminal.
IN
Connected to VC.
IN
Auto clear terminal.
Signal is input to reset the LSI to the initial state when power is applied. Temporarily set to
"L" level the moment power is applied, at this time the LSI is reset. Thereafter set at "H" level.
Signal to sound buzzer (2.0kHz).
A: key touch sound.
B: Completion sound.
Terminal not used.
Oven lamp and Fan motor driving signal.
To turn on and off the shut off relay(RY1). The square waveform voltage is delivered to the
RY1 driving circuit and RY2 control circuit.
Description
22
0.1 sec
A
2.0 sec
B
16.7 msec.
H : GND
L : -5V
During cooking