DOOR SENSING / THIRD DOOR/ PRIMARY INTERLOCK AND MONITOR SWITCHES ADJUSTMENT
If the door sensing switch, primary interlock switch, third
door switch and monitor switch do not operate properly due
to a misadjustment, the following adjustment should be
made.
1. Loosen the two (2) screws holding latch hook to the oven
cavity front flange.
2. With door closed, adjust latch hook by moving it back and
forth, and up and down. In and out play of the door
allowed by the upper and lower position of the latch hook
should be less than 0.5mm. The vertical position of the
latch hook should be adjusted so that the door sensing
switch, primary interlock switch and third door switch are
activated with the door closed. The horizontal position of
the latch hook should be adjusted so that the plunger of
the monitor switch is pressed with the door closed.
3. Secure the screws with washers firmly.
4. Check the all switches operation. If each switch has not
activated with the door closed, loosen screw and adjust
the latch hook position.
After adjustment, check the following.
1. In and out play of door remains less than 0.5mm when in
the latched position. First check upper position of latch
hook, pushing and pulling upper portion of door toward
the oven face. Then check lower portion of the latch
hook, pushing and pulling lower portion of the door
toward the oven face. Both results(play in the door)
REMOVAL
1. Disconnect oven from power supply.
2. Push the open button and open the door slightly.
3. Insert an putty knife (thickness of about 0.5mm) into the
gap between the door stopper and the choke cover to
free engaging parts as shown in Figure C-8.
4. Try the principles of the lever and lift up the door stopper.
5. Now, the door stopper is free from the door assembly.
6. Release two (2) pins of door panel from two (2) holes of
upper and lower oven hinges by lifting up.
7. Now, door assembly is free from oven cavity.
8. Insert an putty knife (thickness of about 0.5mm) into the
gap between the choke cover and door frame as shown
in Figure C-8 to free engaging parts.
9. Try the principles of the lever and lift up the choke cover
by inserting a putty knife as shown Figure C-8.
10.Release choke cover from door panel.
11.Now choke cover is free.
1
Choke Cover
13
11
12
10
7
9
8
Figure C-8. Door Disassembly
12.Release door panel from nine (9) tabs of door frame by
sliding door panel downward.
DOOR REPLACEMENT
Door stopper
2
3
4
5
6
Door Frame
Putty Knife
should be less than 0.5mm.
2. The door sensing switch, third door switch and primary
interlock switch interrupt the circuit before the door can
be opened.
3. Monitor switch contacts close when door is opened.
4. Re-install outer case and check for microwave leakage
around door with an approved microwave survey meter.
(Refer to Microwave Measurement Procedure.)
LATCH
HEADS
SWITCH
LEVER
Figure C-7. Latch Switch Adjustments
13.Now, door panel with sealer film is free.
14.Tear sealer film from door panel.
15.Now, door panel is free.
16.Slide latch head upward and remove it from door frame
with releasing latch spring from door frame and latch
head.
17.Now, latch head and latch spring are free.
18.Remove door screen from door frame by releasing two
(2) tabs.
19.Now, door screen is free.
RE-INSTALL
1. Re-install door screen to door frame by fitting two (2) tabs
of door frame to two (2) holes of door screen.
2. Re-install the latch spring to the latch head. Re-install the
latch spring to the door frame. Re-install latch head to
door frame.
3. Re-install door panel to door frame by fitting nine (9) tabs
of door frame to nine (9) holes of door panel.
4. Hold the door panel to the door frame by sliding the door
panel upward.
5. Put sealer film on door panel. Refer to "Sealer Film"
about how to handle new one.
6. Re-install choke cover to door panel by pushing.
7. Catch two (2) pins of door panel on two (2) hole of upper
and lower oven hinges.
8. Re-install the door stopper to the door assembly.
Note: After any service to the door;
(A) Make sure that door sensing switch and secondary
interlock switch are operating properly. (Refer to
chapter "Test Procedures".).
(B) An approved microwave survey meter should be
used to assure compliance with proper microwave
23
LATCH HOOK
DOOR SENSING
SWITCH
MONITOR
SWITCH
THIRD DOOR
SWITCH
PRIMARY INTERLOCK
SWITCH
R-312AW
R-312AK