Digistar 410002 설치 매뉴얼 - 페이지 8
{카테고리_이름} Digistar 410002에 대한 설치 매뉴얼을 온라인으로 검색하거나 PDF를 다운로드하세요. Digistar 410002 9 페이지. Rotation counter for ez/tmr xx10 series indicators
INDICATOR SETUP INSTRUCTIONS
To turn on Rotation Counter function on Digi-Star EZ/TMR xx10-
Series Indicators
4 6
4301
3
7
5
1
To Set Drive Ratio
The Drive Ratio is number of turns seen by sensor divided by number of mixing rotations. For
example if 1000 RPM from the Tractor PTO equals 20 RPM of the mixing auger the Drive
Ration will be 50.0.
4302
20.25
2
3
8
Rotation Counter Installation Manual for EZ/TMR xx10 Series Indicators
2
1
1
1. Enter 4301 press
(Enter 421 on older Digi-Star EZ3 Indicators.)
2. Press
to pick COUNTR (REV on EZ3)
option.
3. Press
.
4. Press
5. Enter number of rotations.
6. Press
rotation counter counts down.
Counter reaches zero, alarm light and buzzer on.
7. Press
to acknowledge and clear alarm.
1. Enter 4302 press
(Enter 422 on older Digi-Star EZ3 Indicators.)
2. Enter drive ratio (in this example 20.25).
3. Press
.
Indicator Setup
.
.
D4044