OPERATION INSTRUCTION
I: OFF LINE M ODE:
Switch on the power, the system accesses the OFFLINE mode.
A. Adjust the volume: turn CHA/CHB button to adjust the input level of CHA/CHB.
B. Setup the amplifier ID:
Press CHA button for about 3 seconds, the LCD shows as follows:
Then, turn CHA to change the amplifier ID from 1 to 255. Press CHA button again
and save the setting.
C. Load program
Press the CHB button for about 3 seconds, the LCD shows as follows:
Then, turn CHA to select one program(1-11) . Press CHB button again, save the
setting and load the selected program. At the same time, the LCD shows:
LOADING ..........Several seconds later, the LOADING is finished and the system
return the menu
D. SETUP VOLUME PROTECT
Under the menu of LOAD PROGRAM , press the CHB button again for about 3
seconds and then the LCD shows as follows:
Turn the CHB button to switch on/off AUTO MUTE. Then, press the CHB button again
to save the setting.
AUTO MUTE: ON. When the power is on, the volume of CHA/CHB is MUTE
automatically.
AUTO MUTE: OFF. When the power is on, the volume of CHA/CHB comes to the
setting when power was off last time.
NOTE:
1.Among 11 programs, No.11 is not used under the online mode without PEQ,
XOVER and DELAY. The other 10 programs can be saved and recalled on the
online mode.
2. The volume is mute automatically after ever y LOAD PROGRAM.
3. When the system switches from the online mode to the offline, the system can
load the program that is saved under th online mode. At the same time, the
volume is mute automatically.
6
SET UP AMPLIF IER
DEVICE
NO.#1
LOAD PROGRAM P
NO PEQ+XOVER+DELAY
VOLUME MUTE PROTECT
AUTO MUTE ON
I D
Amplifier ID
Program Number
11
Program name