Sharp 19U-M100 서비스 매뉴얼 - 페이지 12

{카테고리_이름} Sharp 19U-M100에 대한 서비스 매뉴얼을 온라인으로 검색하거나 PDF를 다운로드하세요. Sharp 19U-M100 35 페이지.

19U-M100,19U-M100S
CU19M10
Vertical-Size, V-Linearity and
V-S Correction Adjustments
1. Receive a good local channel.
2. Enter the service mode DEF category and select the
adjustment "D02" for Vertical Size, "D05" for V-
Linearity and "D06" for V-S Correction Adjustment.
3. Set in order "D05" for V-Linearity, "D06" for V-S
Correction and set the data to get the best linearity.
4. Then adjust "D02" data until it become a proper
vertical size.
Horizontal Position Adjustment
1. Receive a good local channel.
2. Enter the service mode DEF category and select the
adjustment "D01".
3. Adjust "D01" data value to center the picture.
Vertical-Phase Adjustment
1. Receive a good local channel.
2. Enter the service mode DEF category and select the
adjustment "D03".
3. Adjust "D03" bus data to get the most acceptable
vertical position.
Note: The step range is 20 (032) ±10 steps.
Caption Position Adjustment (Horizontal)
1. Receive a good local channel.
2. Enter the service mode DEF category and select the
adjustment "D04".
3. A black text box will appear on the screen. (see
Figure C. below)
4. Adjust "D04" data value to balance the text box
position in the center (A=B).
A
Figure C.
12
B