Flash Rom Version Up Procedure
Download Procedure (cont'd)
11.
Main Body Side:
Wait until the words "Processing finished. Turn OFF the power."
appears on the operation panel.
The appearance of "Processing finished. Turn OFF the power."
indicates the completion of the download (writing to ROM).
Turn the power OFF and remove the USB cable.
12.
Terminate the program, and turn ON the power of the main body.
Note: To make a second connection with another machine, select the
[File] .and [Reconnect] in the menu bar on the maintenance program at
the time the USB is being reconnected.
Repeat the previous steps (7) through (12)
Quick Reference Guide: AR-M207, M165, M162
Failed Downloads
The following actions will result in a failed download. Therefore ,do not:
•
•
Corrective Actions for Failed Downloads
Turn the power OFF and ON again.
1.
2.
3.
Flash ROM Version Up Procedure (cont'd)
Switch OFF the main body of AR-M207/M162/M165, or
Disconnect the download cable (USB cable)
If "Download mode." is displayed on the operation panel, perform
downloading again.
If "Download mode." is not displayed on the operation panel, turn OFF
the power and press and hold the 4 key and the CA key while turning
ON the power. If "Download mode." is displayed on the operation
panel LED of the machine, perform downloading again.
If "Download mode." is still not displayed, replace the
MCU/Panel/IMC2/Fax.
41