Sharp SJ-47L-A2G-A2S 서비스 매뉴얼 - 페이지 13
{카테고리_이름} Sharp SJ-47L-A2G-A2S에 대한 서비스 매뉴얼을 온라인으로 검색하거나 PDF를 다운로드하세요. Sharp SJ-47L-A2G-A2S 32 페이지.
2. DEFROSTING
(1) No defrosting operation is necessary
No defrosting operation is necessary.
As this machine is so designed that a built-in
evaporator cools air and a fan circulates cooled
air, neither the freezer nor the refrigerator is
frosted, though the evaporator is frosted.
The frosted evaporator is defrosted automatically
due to the function of defrosting timer and heater,
requiring no defrosting operation.
(3) The following circuit diagrams in the table show automatic defrosting function of the refrigerator with
timer and defrost thermostat.
Operation
1. Cooling
(Normal)
2. Defrosting
(Time 20 to 30 min.)
3. Drain
(Time approx. 5 min.)
4. Restart
(Time approx. 5 min.)
Electric diagram
Defrost thermostat ON
Compressor running
Timer motor running
Thermostat
Timer contact
Thermo. fuse
Defrost heater
Defrost
thermostat (ON)
Figure F-3.
Defrost thermostat ON
Compressor stops
Timer motor stops
Thermostat
Timer contact
Thermo. fuse
Defrost heater
Defrost
thermostat (ON)
Figure F-4 .
Defrost thermostat OFF
Compressor stops
Timer motor running
Thermostat
Timer contact
Thermo. fuse
Defrost heater
Defrost
thermostat (OFF)
Figure F-5.
Defrost thermostat OFF
Compressor running
Timer motor stops
Thermostat
Timer contact
Thermo. fuse
Defrost heater
Defrost
thermostat (OFF)
Figure F-6.
(2) Where is melted frost brought
1. Melted frost is brought into the evaporating
pan at the back of the set and is evaporated
here by the heat of compressor.
2. Be sure to use Evaporating pan as inserted
so as to be level with the outer case.
The integration timer integrates running
time of the compressor. When it reaches
cycle time of defrost timer, the timer
contact is changed to start defrosting.
TM
COMP
The timer contact is changed to start
defrosting, the timer motor stops, and
power is supplied to the defrost heater.
It takes about 20 to 30 min. to defrost.
When little frosted, the defrosting takes
little time. When much frosted, the def-
TM
COMP
rosting takes much time.
When the defrost thermostat becomes
OFF, the timer motor starts running.
During the operation time (delay time
of defrost time) defrosted water is
drained outside the refrigerator.
TM
COMP
Timer contact is changed to cooling
operation and the compressor starts
running and the timer motor stops.
Defrost thermostat contact becomes ON
when it's cooled. And the timer motor
starts running. (Figure F-3.)
TM
COMP
13
SJ-43L-A2
SJ-47L-A2
Description