Digital Acoustics EDW-110 사용자 설명서 - 페이지 14

{카테고리_이름} Digital Acoustics EDW-110에 대한 사용자 설명서을 온라인으로 검색하거나 PDF를 다운로드하세요. Digital Acoustics EDW-110 16 페이지. Ed/es series ii3 ip intercom

P
E O
O
PTION
A PoE (Power over Ethernet - 802.3af compatible) option is available on all
models in the ED and ES lines.
• Each ED or ES intercom will draw 7 Watts from your network switch
or injector
• On models with the PoE and integrated 2-port switch options, PoE
does not pass through to other devices connected to the 2
• Do not plug power into the external power jack and connect the
Intercom to a PoE power source at the same time
T
ROUBLESHOOTING
Verify power connections. The "Active" or LD10 LED on should be on or
flashing.
Verify that the "Link" or LED is on solid. If not, a valid network
connection is not present.
ii3 Intercoms may operate across some firewalls or VPN's. They will
need to be configured locally (for setup) and will need to be assigned to
the STATIC IP addresses of the TalkMaster PC.
If the intercoms have been configured for DHCP and no DHCP server is
available, re-power the intercom while holding down the Volume Up and
Volume Down buttons. Wait 15 seconds, then Search for the Intercoms
again and assign a static IP address.
If you cannot detect any intercoms using the TalkMaster Intercom
Configuration Utility screen try directly connecting the PC (running
TalkMaster) to the ii3 intercom using a crossover cable (disconnected
from the network).
PC running
TalkMaster
To reset the Intercom's configuration back to factory defaults, re-power
the intercom while holding down the TALK and Volume Up buttons.
This will erase the Intercom's IP Address settings, Intercom Name and
all options. Wait 15 seconds, then Search for the Intercoms again and
re-configure the Intercom.
Crossover Cable
- 14 -
nd
port
ii3
intercom