Crestron 4 Series 빠른 시작 매뉴얼 - 페이지 3

{카테고리_이름} Crestron 4 Series에 대한 빠른 시작 매뉴얼을 온라인으로 검색하거나 PDF를 다운로드하세요. Crestron 4 Series 6 페이지. Control processor for zūm lighting control system
Crestron 4 Series에 대해서도 마찬가지입니다: 빠른 시작 매뉴얼 (8 페이지), 빠른 시작 매뉴얼 (8 페이지), 빠른 시작 매뉴얼 (6 페이지), 빠른 시작 (5 페이지), 빠른 시작 매뉴얼 (6 페이지), 빠른 시작 매뉴얼 (2 페이지), 빠른 시작 매뉴얼 (2 페이지), 시작하기 (2 페이지), 빠른 시작 매뉴얼 (2 페이지), 빠른 시작 매뉴얼 (12 페이지)

Crestron 4 Series 빠른 시작 매뉴얼
DIN-AP4
4-Series™ DIN Rail Control System
Observe the following when connecting the DIN-AP4:
NOTE: To comply with the European Directive (CE), Crestron
recommends using shielded CAT5e cable as a minimum for PoE power.
Use Crestron power supplies for Crestron equipment.
l
Power may be provided to the DIN-AP4 by a 24 VDC power supply (not
l
included) via the PWR port or a single Ethernet cable via the LAN
PoE port. A Crestron PoE (Power over Ethernet) power supply, such as
the PWE-4803RU, or a PoE-capable network switch is recommended
for the latter (both not included).
Connect the chassis ground lug to a known earth ground circuit (for
l
example, building steel) to ensure that the DIN-AP4 is grounded
properly.
Apply power after all connections have been made.
l
COM 1–2 Connections
Port
RS-232
G
GND
GND
TX
TX (from DIN-AP4)
TX- (from DIN-AP4)
RX
RX (to DIN-AP4)
RX+ (from DIN-AP4)
RTS
RTS (from DIN-AP4)
TX+ (from DIN-AP4)
CTS
CTS (to DIN-AP4)
RX- (to DIN-AP4)
1. RS-422 transmit and receive are balanced signals that require two lines plus a ground
in each direction. RXD+ and TXD+ should idle high (going low at start of data
transmission). RXD- and TXD- should idle low (going high at start of data
transmission). If necessary, RXD+/RXD- and TXD+/TXD- may be swapped to maintain
correct signal levels.
2. A ground terminal connection is recommended but not required.
1
RS-422
RS-485
2
GND
TX-/RX-
Not used
TX+/RX+
Not used
Configure the Control System
The control system may be configured using the provided web
configuration interface. The interface can be accessed using the control
system IP address or the XiO Cloud® service.
Configuration via IP Address
To access the web configuration interface using the control system
IP address:
NOTE: The control system ships with DHCP enabled. A DHCP server is
required to access the web configuration interface via the device
IP address.
1. Connect the control system to the network.
2. Use the Device Discovery tool in Crestron Toolbox™ software to
discover the control system and its IP address on the network.
3. Enter the control system IP address into a web browser.
Configuration via XiO Cloud
The XiO Cloud service allows supported Crestron devices across an
enterprise to be managed and configured from one central and secure
location in the cloud. Supported devices are configured to connect to the
service. Use of the service requires a registered XiO Cloud account.
NOTE:
The device may be disconnected from the service by navigating to
the Cloud Services tab in Crestron Toolbox software (Functions >
Device Info > Cloud Services). For details, refer to the Crestron Toolbox
help file.
Quick Start
3