Digital Electronics Corporation PL-3900T Series 설치 매뉴얼 - 페이지 6
{카테고리_이름} Digital Electronics Corporation PL-3900T Series에 대한 설치 매뉴얼을 온라인으로 검색하거나 PDF를 다운로드하세요. Digital Electronics Corporation PL-3900T Series 19 페이지.
[Power Management option]-[Turn off hard disks] selection to turn the hard disk off
when the unit is not being operated. A setting of 5 minutes is recommended.
• Do not vibrate the hard disk continuously at the same frequency. Doing so may cause
the hard disk to reduce transfer speeds or stop temporarily.
Internal Switches
To operate the internal switches, uninstall the control box and the front module.
SEE
Installation/uninstallation of the front module and the control box (page 13)
• Make sure to turn off the power supply before using the switches. Adjusting the
switches while power is supplied may cause errors.
1.
Internal switches of the control box
Bottom face of the control box
Switch
Switch Name
Location
SW1 System Set SW
Serial Mode
SW2
Select SW
CI(RI)/+5V
SW3
Changeover SW
CI(RI)/+5V
SW4
Changeover SW
SW1
Compatible
Factory
I/F
Settings
See
–
System
Set Switch
All OFF
COM1
(RS-232C)
COM2
CI(RI)
COM1
CI(RI)
6
SW2
SW3
(CI)RI
5V
Description
10-point dip switch. For System Set
SW and the factory settings details,
see
System Set Switch.
10-point dip switch. Designates COM1
communication settings. For Serial
Mode Select SW details, see
Mode Select Switch.
Changes # 9 pin (CI(RI) <---> +5V).
Changes # 9 pin (CI(RI) <---> +5V).
SW4
Serial