Installing Device
2.1.1 Mounting the Device to a Rack
Note
For detailed dimensions of the device with either rack, DIN rail or panel hardware
installed, refer to
2.1.1
Mounting the Device to a Rack
For rack mount installations, the RUGGEDCOM RS1600 can be equipped with rack
mount adapters pre-installed.
Note
The chassis features multiple mounting holes, allowing the rack mount adapters to
be installed up to 25 mm (1 in) from the face of the device.
To secure the device to a standard 48 cm (19 in) rack, do the following:
1.
Make sure the rack mount adapters are installed on the correct position on the
chassis.
Figure 2.1
2.
Insert the device into the rack.
Note
Since heat within the device is channelled to the enclosure, it is recommended
that 1 rack-unit of space, or 44 mm (1.75 in), be kept empty above the device.
This allows a small amount of convectional airflow.
Forced airflow is not required. However, any increase in airflow will result in a
reduction of ambient temperature and improve the long-term reliability of all
equipment mounted in the rack space.
3.
Secure the adapters to the rack using the supplied hardware.
8
All manuals and user guides at all-guides.com
"Dimension Drawings (Page
1
Rack Mount Adapter
1
Rack Mount Adapters
23)".