Amendment to the Function Manual
5.1
"Order Creation" interface
If you want to access the user-specific scripts on this dialog, WinCC-Dialog provides the
following properties and events:
Properties
● PCellName (In)
– Name of the PCell to connect to
● FormulaCategory (Out)
– Name of the formula category which is selected/calculated.
● Recipe (Out)
– Name and Version of the formula or recipe which is selected.
● RecipeName (Out)
– Name of the formula or recipe which is selected.
● RecipeVersion (Out)
– Version of the formula or recipe which is selected.
● ProductName (Out)
– Name or the product which is associated with the selected Recipe
– Will be updated if Recipe has changed
● ProductCode (Out)
– Code or the product which is associated with the selected Recipe
– Will be updated if Recipe has changed
● MinRecipeSize (Out)
– Minimum amount of selected recipe
– Will be updated if Recipe has changed
● MaxRecipeSize (Out)
– Maximum amount of selected recipe
– Will be updated if Recipe has changed
● UOM (Out)
– Unit of measurement which is associated with the selected recipe
– Will be updated if Recipe has changed