Battery life
The battery life of the batteries used in the transponder depends on various factors and settings.
Note
To achieve optimal battery life, you must make appropriate adjustments to the delivery state
since it was designed to allow fast commissioning.
Factors that reduce the battery life:
• Continuous use at temperatures below 0°C
Parameter assignment that reduces the battery life:
• Short sign-of-life cycle times < 60 seconds
• Short node search cycle times < 60 seconds
Operations that reduce the battery life:
• Reconfiguration of the transponder via the Locating Manager
• Firmware update (recommendation: change the battery after firmware updates)
With the setting 1 Hz TDOA blinking and 10 minutes sign-of-life interval, the transponder
battery lasts for up to one year at room temperature. The use of motion detection allows the
transponder to switch to an energy-saving mode on standstill. This increases the battery life
to up to five years.
Battery voltage status
The battery voltage status is transferred to the Locating Manager. The following three statuses
are possible. Be sure to only use approved batteries, see section "Technical specifications
(Page 23)". At 2.8 V, a low power warning is sent to the Locating Manager. If the battery has the
status "empty", the transponder switches off autonomously. The values in the following table are
for a room temperature of 20 °C.
Battery voltage status
Full to 10% remaining capacity
~5% remaining capacity
Empty
Communication with the Locating Manager
After sending a heartbeat to the Locating Manager, the transponder is ready to receive for a
defined period of time. During this time, data such as configuration changes or firmware update
data can be initiated on the transponder. Applications that require the transponder to transmit,
such as TDOA blinking or distance measurements, are paused after the heartbeat for this period
and only continued afterwards. TDOA or distance measurements also take place during the
actual transmission of configuration and firmware update data.
14
Displayed battery voltage in the Locating Manager
3.3 V
3.0 V
2.4 V
Operating Instructions, 08/2023, C79000-G8976-C687-02