Command "Get Version"
This command queries the protocol version. The default value is 1.
URI
Parameter
Return value
Command "Get Tags"
This command queries a list of all configured transponders in the Locating Manager Server.
URI
Parameter
Return value
Command "Set Display Theme"
This command selects and activates the "theme" visible on the display and the transfer of the
text and barcode to be displayed. Texts are set to "empty" if they are not transferred in this
call. If one text is invalid, the others are still set.
URI
Parameter
Return value
SIMATIC RTLS4084T
Operating Instructions, 04/2021, C79000-G8976-C626-02
"agilion.wls.epaper. get_version"
None
Consists of:
Version of the protocol, type: UInt32
"agilion.wls.epaper.get_tags"
None
Consists of:
Result, type: UInt32
Field with the following parameters:
TransponderID, type: UInt64
ProductID, type: UInt64
FirmwareVersion, type: String
"agilion.wls.epaper.set_display_theme"
TransponderID, type: UInt64
ThemeID, type: UInt32
Field with the following parameters:
FieldID, type: UInt32
Text, type: String
Consists of:
Result, type: UInt32
Field with the following parameters:
RPCResult, type: UInt32
1 ... n FieldResults, type: UInt32
Programming interface
3.3 RPC calls
17