Siemens SIMOGEAR 2730 설치 및 작동 지침 - 페이지 41

{카테고리_이름} Siemens SIMOGEAR 2730에 대한 설치 및 작동 지침을 온라인으로 검색하거나 PDF를 다운로드하세요. Siemens SIMOGEAR 2730 48 페이지. Geared motor with rotary encoder for safety-relevant applications

Brake type
L8 (08E)
L16 (10E)
L32 (12E)
L60 (14E)
L80 (16E)
L150 (18E)
SIMOGEAR functionally safe rotary encoder
Operating Instructions, 01/2024, A5E53220857A/RS-AA
Rated braking tor‐
Working capacity
que T
until the maxi‐
br
mum air gap W
at 100 rpm
reached
Nm
MJ
3
86.4
4
86.4
5
75.6
6.3
75.6
8
64.8
10
54
4
108
8
108
10
108
13
108
16
108
20
80
8
190
14
190
18
190
23
173
32
141
40
110
25
204
35
204
38
187
50
159
60
159
25
264
35
264
50
264
63
264
80
264
100
173
45
273
60
273
80
273
100
273
125
273
150
273
Ensuring functional safety
Nominal air gap s
LN
is
V
mm
0.2
0.2
0.2
0.2
0.2
0.2
0.2
0.2
0.2
0.2
0.2
0.2
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.4
0.4
0.4
0.4
0.4
0.4
4.5 Technical data
Maximum
air gap s
Lmax
mm
0.6
0.6
0.6
0.6
0.5
0.5
0.6
0.6
0.6
0.6
0.6
0.5
0.7
0.7
0.7
0.7
0.6
0.5
0.7
0.7
0.7
0.6
0.6
0.7
0.7
0.7
0.7
0.7
0.6
0.8
0.8
0.8
0.8
0.8
0.8
39