2.3

Electrical installation of the encoder

Inadequately qualified personnel
If the encoder is electrically installed by inadequately qualified personnel then the functional
safety can be disabled.
Only qualified personnel are authorized to carry out the work.
These persons must be knowledgeable about:
• Topics relating to functional safety
• Legislation, safety regulations and standards for functional safety
• Content of the detailed operating instructions provided
Premature damage or destruction of the encoder
Electrostatic discharge can cause the encoder to fail.
Do not touch the connector pins.
Do not exceed the following tolerances regarding the motor supply voltage according to
EN 60034-1 Range A.
• Voltage ±5 %
• Frequency ±2 %
Especially observe the following topics in the operating instructions Sendix SIL Encoders for
Functional Safety from the Kübler company:
• Functional safety
• Electrical installation, EMC and general notes
• Data transfer to encoder evaluation
Incorrect connection assignment of the encoder
The connection assignment in the operating instructions Sendix SIL Encoders for Functional
Safety from the Kübler company is not applicable for the SIMOGEAR geared motor with
rotary encoder.
The valid connection assignment is coordinated with the geared motor.
Refer to these operating instructions for the connection assignment of the SIMOGEAR
geared motor with encoder.
BA 2730
Operating Instructions, 02/2021, A5E36448105A/RS-AG
WARNING
WARNING
WARNING
Securing functional safety
2.3 Electrical installation of the encoder
13