3 Commissioning
•
A message telling you that the data have been successfully loaded is
displayed.
Acknowledge this message by pressing the "OK" softkey.
Commissioning of the drive is now complete and an NCK reset is automatically
performed.
3.2.3
Relevant machine data
Note
Leave machine data MD 32640 STIFFNESS_CONTROL_ENABLE at value "0".
Note
Analog drives do not support the DSC function.
Enter your spindle pitch in the setpoint scaling for linear axes in axis-specific
Note
machine data MD31030 ($MA_LEADSCREW_PITCH).
Enter your ratio between motor and ball screw in machine data MD31050 and
MD31060.
Note
In SW 4.8, you do not need axis machine data MD13070
($MN_DRIVE_FUNCTION_MASK) bit 2 Deactivate axial parameter access on
encoder drivers because you can also operate rotary encoders.
Leave MD13070 bit 2 at default value "0".
Parameterize the encoder data in the NC axis machine data with the drive wizard.
The analog axis is ready for operation when the following conditions are met:
•
You are using TTL encoders, they are inserted into interfaces X231 or X232
and ports X202 and X203 are free.
•
The motor has a maximum speed of 6000 rpm, and the ratio between the
motor and the ball screw is 1:1.
The BICO interconnections in the commissioning file are SINUMERIK compatible.
X122 pin 1 P840 ON/OFF(OFF1) = CU-r0722.1 and X122 pin 2 P864 (system
pressure available for HLA or ALM ready for electric drives) = CU-r722.0. In the
procedure, the enable signals at the PLC interface are identical to the enable
signals of the electrical axes.
3.2.4
Values displayed on the user interface
The factors are set in such a way that the following results can be read.
•
The rotation of a rotary axis at 1000 rpm, for example, is displayed on the user
interface as 1 m/min .
•
An axis traveling at 6 m/min is also displayed as 6 mm/min.
The SINAMICS HLA module internally calculates the velocity actual values.