Siemens SITRANS LPS200 사용 설명서 - 페이지 23

{카테고리_이름} Siemens SITRANS LPS200에 대한 사용 설명서을 온라인으로 검색하거나 PDF를 다운로드하세요. Siemens SITRANS LPS200 33 페이지. Rotating paddle switch

8.2

Performance

Alarm delay
Sensitivity
Approximate minimum material density
8.3

Alarm output

SITRANS LPS200
Operating Instructions, 04/2019, A5E34210883-AB
1 rpm model (storage applications)
5 rpm model (process applications)
Standard measuring vane
Hinged measuring vane
Rectangular measuring vane (98 x 250 mm)
Approx. 1.3 s
Approx. 0.26 s
Adjustable spring tension position
Optional measuring vanes available, depend-
ing on customer sensitivity requirements
100 g/l (6.2 lb/ft
) when vane is covered by
3
10 cm (4 inch) of material
200 g/l (12.5 lb/ft
) when vane is covered by
3
more than 10 cm (4 inch) of material
35 g/l (2.2 lb/ft
) when vane is covered by
3
10 cm (4 inch) of material
70 g/l (4.4 lb/ft
) when vane is covered by
3
more than 10 cm (4 inch) of material
15 g/l (0.9 lb/ft
) when vane is covered by
3
10 cm (4 inch) of material
20 g/l (1.2 lb/ft
) when vane is covered by
3
more than 10 cm (4 inch) of material
See Measuring vanes (Page 31) for more
information.
Microswitch or relay SPDT or DPDT contact
5 A at 250 V AC, non-inductive
Microswitch or relay SPDT or DPDT contact
4 A at 30 V DC, non-inductive