Siemens SITRANS LPS200 사용 설명서 - 페이지 29

{카테고리_이름} Siemens SITRANS LPS200에 대한 사용 설명서을 온라인으로 검색하거나 PDF를 다운로드하세요. Siemens SITRANS LPS200 33 페이지. Rotating paddle switch

High temperature model
Compact version
Process temperature
-25 ... +600 °C
(-13 ... +1 112 °F)
Zone 20 (ATEX Catego-
ry 1D IECEx EPL Da)
Zone 21 (ATEX Catego-
ry 2D IECEx EPL Db)
Thread length
BSP: 20.5 mm (0.81 inch)
NPT: 24 mm (0.94 inch)
Ambient temperature:
-25 ... +50 °C
(-13 ... +122 °F)
Note
• For heavy material, only top mounting of paddle switch is recommended.
• Compact LPS200 is recommended for side mounting on bins for low or intermediate
material levels.
For 35 x 106 mm boot-shaped, and 65 x 210 mm hinged measuring vanes, add 16 mm
1)
(0.63 inch) to extension length.
A = 200 mm (7.87 inch) for 250 ºC (482 ºF) = 400 mm (15.74 inch) for 600 ºC (1 112 ºF).
2)
For use with all approval options except CSA Class II. See Temperature (Page 26) more
3)
details.
SITRANS LPS200
Operating Instructions, 04/2019, A5E34210883-AB
Extended
L = length
3)
100 mm
3.94 inch
150 mm
5.91 inch
200 mm
7.87 inch
250 mm
9.84 inch
300 mm
11.81 inch
Angle extension
125 ... 300 mm
(4.92 ... 8.46 inch)
Rope option
Rope fixing
2 000 mm (78.74 inch)
standard, can be shortened
by the customer, total length
available 10 000 mm
(393.7 inch)
29