5
FUNCTIONS
5.1
Load detection function
When the programme has started, the water supply times of the
solenoid valves are added. 2 load levels are detected:
►
Water supply times < 60-70 seg = partial load (it depends on
the programm)
►
Water supply times > 65 seg = full load (it depends on the
programm)
N: Nivel
● Points of load detection function
Water supply times (t1+t2+t3+t4...)
5.2
Foam detection function
If during the rinse is reached the level I of the pressure switch, the
module understand that there is foam in the drum cause of over
dosage of detergent. In this case, the spin will be stopped, will be
drained, and there will be an extra rinse.
209_58300000115677_ara_en_f.doc – 26.03.08