REPLACEMENT AND ADJUSTMENT
4. On the maintenance unit use a plus
(+) screwdriver to turn the screw at [A]
counter-clockwise until the tip of the
upper triangle [B] aligns with the tip of
the lower triangle [C]. This unlocks the
carriage.
Important: Be sure to rotate screw [A]
counter-clockwise.
5. Push the unlocked carriage to the
middle of the platen above the
transport belt.
6. Remove the lock screw [A] ( x1) and
bracket [B] ( x2).
7. Disconnect the maintenance HP
sensor [C] ( x1).
8. While pressing down on the blade [A],
pull the maintenance unit toward you to
remove it.
[A]
[A]
6
15 July 2005
[B]
Unlock
[C]
G707R914.BMP
[C]
[B]
P2W-3-8A.BMP
[A]
P2W-3-8B.BMP