PREPARATION
The following preparations are required before disassembling and assembling the camera.
1. Prepare the Jigs; tools and testers (Refer to the table of Jigs, tools and testers.)
2. Make the preparation for adjustment with referring [Preparation of Adjustments].
Preparation of Adjustments
[Required equipment]
Programmed software for 77750(CD-ROM: 95901 P426)
Computer (PC)
OS: Windows XP SP2
Free disk space (HD): 500MB or more
SD card 6 pieces (16Mb or above) --- for FW
SD card reader or USB cable (I-USB17) --- For connecting with PC
1. Prepare SD card (6 pcs) for adjustment
*prepare SD card (6pcs) (Format with K-50 before use)
1. For repair FW (For replaced T100)
2. For product FW (Firmware: Latest version/running change version 1pcs each)
3. For test mode ON / OFF (For confirming full version, 1 pcs each)
4. For Initial set (Initialize / Product shipment)
2. Installing procedure of the Adjustment Software (Setting of the Computer)
*Set programmed software for 77750 (CD-R) to CD-ROM drive.
1. Copy the [77750] folder from the programmed software contained in the CD-ROM to [C: drive]
*Copy the following files from CD-RPM
2. Copy the file from [01_Replaced T100] folder to SD card --- For replaced main PCB FW (Firmware)
3. Copy the file from [02_GM_FW] folder to SD card --- For Product FW (Firmware)
4. Copy the file from [Test mode ON] and [Test mode OFF] folder in the [03_MODE SET] to each SD card.
(Since the name of all files is the same, you should distinguish them by name label etc.)
5. Copy the file from [Initialize Set] folder in the [03_MODE SET] to each SD card. --- For Initial set (Initialize)
CPU: 1GHz or more
Port: USB2.0
77750 - 2/12 -
RAM: 512MB or more
---1pcs
--- 2pcs
----2pcs
---1pcs