Ricoh A077-29 기술 게시판 - 페이지 35

{카테고리_이름} Ricoh A077-29에 대한 기술 게시판을 온라인으로 검색하거나 PDF를 다운로드하세요. Ricoh A077-29 38 페이지.

Ricoh A077-29 기술 게시판
SUBJECT: Remarks for replacing the fusing thermoswitch
PREPARED BY: S. Orita
CHECKED BY:
CLASSIFICATION:
Action Required
Troubleshooting
Retrofit Information
We have been informed that some field technicians might not have installed the fusing
thermoswitch bracket properly. As a result, service code #E52 may be displayed because
of an incorrect gap between the thermoswitch and the hot roller.
To prevent this, a note on thermoswitch bracket installation has been added to the
"FUSING THERMOSWITCH REPLACEMENT" procedure. Please correct your service
manual page 5-77.
Service Manual (Page 5-77)
7.6 FUSING THERMOSWITCH REPLACEMENT
[B]
[C]
1. Turn off the main switch and unplug the power supply cord.
2. Open the front cover.
3. Remove the upper inner cover (3 screws).
4. Remove the drum unit. (See Drum Replacement.)
5. Hold down the top of upper unit and open the upper unit by pushing the release lever.
Technical Bulletin
FROM: 2nd Technical Support Section
Revision of service manual
Information only
Other
[D]
[C]
[A]
No. RTB-013
DATE:
January. 31, 1994
PAGE: 1 of 2
MODEL: E7 Series
(A076/A077)